• Compact yet Highly Accurate Flowmeter 

Flow Level Pressure

Compact yet Highly Accurate Flowmeter 

Feb 14 2014

With Sitrans FC410, Siemens (Germany) presents the lightest and most compact Coriolis flowmeter currently available, featuring a high measuring accuracy of 0.1 percent. With dimensions of only 265(L) x 280(H) x 90(B) millimeters and a weight of 4.6 kilograms in the smallest version (DN 15), the meter is ideal for machine and plant construction or for frame-mounted equipment. The combination of compact design, high accuracy, IP67 degree of protection and a wide variety of functions orients Sitrans FC410 toward use in almost any facility, even where space is very limited.

With the new Mini Flow Link (MFL) concept, Siemens has succeeded in accommodating transmitter functionalities in the sensor. The digitally based MFL permits a much more compact design without additional assembly work. Sitrans FC410 is therefore flexible enough for installation in confined spaces without any compromise in measuring accuracy or reliability. The digital MFL features a very fast signal update of 10 milliseconds and provides not only flow rate data but also the mass, volume, density, and temperature of the medium. The innovative CompactCurve design of the sensor developed by Siemens ensures a high level of reliability due to its stable zero point, low pressure loss, and high immunity to process noise and plant vibrations. Sitrans FC410 is therefore especially suitable for use in challenging applications where accuracy and reliability in measurements of density and mass are required. The flowmeter also works at pressure levels of up to 100 bar and temperatures of -50 to +200 degrees Celsius without any loss of measuring accuracy. 

Sitrans FC410 communicates with Simatic and all other common process control systems via the multidrop-addressable Modbus RTU485 and can be integrated easily into both existing and new systems.Installation and commissioning of the flowmeter require only simple, one-time configuration in the control system with little programming. If a flowmeter is replaced or further flowmeters are connected, the user's settings are automatically transferred. 


Digital Edition

PIN 25.2 Apr/May

May 2024

Safety - Carbon monoxide toxic and flammable gas detection Analytical Instrumentation - Density: A fundamental parameter at critical stages within the petroleum sector - Advancements and...

View all digital editions

Events

The World Biogas Expo 2024

Jul 10 2024 Birmingham, UK

Thailand Oil & Gas Roadshow 2024

Jul 11 2024 Rayong, Thailand

HPLC 2024

Jul 20 2024 Denver, CO, USA

ICMGP 2024

Jul 21 2024 Cape Town, South Africa

Colombia Oil & Gas

Jul 24 2024 Bogata, Colombia

View all events