• Analysis of Sulphur in Automotive Fuels by ASTM D2622-10

Analytical Instrumentation

Analysis of Sulphur in Automotive Fuels by ASTM D2622-10

Mar 09 2013

Rigaku Corporation (USA) recently announced the publication of a new application report describing the analysis of low concentration sulphur in automotive fuels using wavelength dispersive X-ray fluorescence (WDXRF) spectrometry. Rigaku Application Note #XRF 5035 adheres to the American Society for Testing and Materials method ASTM D2622-10 (“Standard Test Method for Sulphur in Petroleum Products by Wavelength Dispersive X-ray Fluorescence Spectrometry”) and highlights the capabilities of the Rigaku Mini-Z Sulphur analyser.

Recent developments in ultra-low sulphur diesel (ULSD) fuel have improved fuel efficiency and created cleaner emissions. The allowable limit of sulphur in fuel oils has been reduced by as much as 15 ppm in many countries, with the likelihood of further restrictions still to come.

For compliance verification, X-ray fluorescence (XRF) spectrometry is the preferred analysis tool for use at distribution terminals, as well as at mobile or stationary testing laboratories. Application Note #XRF 5035 details sample preparation, method calibration and repeatability. For the analysis described in the report, 4 ml of each sample was poured into a special liquid cell with a 2.5 μm Mylar analysis film. “Number 2 diesel fuel” standards and isooctane-based standards were used for calibration for diesel fuel and gasoline respectively.

Measurements were carried out using the Mini-Z Sulphur analyser, a benchtop single fixed-channel WDXRF spectrometer designed to minimise installation requirements such as cooling water, power supply and floor space. It has a built-in control panel designed for easy operation. The Mini-Z Sulphur analyser is equipped with an air-cooled 40 W Cr-target X-ray tube. The RX-9 analysing crystal is optimised for sulphur analysis.

The results show that low concentration sulphur in petroleum-based fuel can be routinely analysed with high precision using the Mini-Z Sulphur analyser, meeting the requirement of the current ASTM D2622-10 method.

A copy of this application report may be requested on Rigaku’s official website at: http://j.mp/ZGIyz7


Digital Edition

PIN 25.2 Apr/May

May 2024

Safety - Carbon monoxide toxic and flammable gas detection Analytical Instrumentation - Density: A fundamental parameter at critical stages within the petroleum sector - Advancements and...

View all digital editions

Events

The World Biogas Expo 2024

Jul 10 2024 Birmingham, UK

Thailand Oil & Gas Roadshow 2024

Jul 11 2024 Rayong, Thailand

HPLC 2024

Jul 20 2024 Denver, CO, USA

ICMGP 2024

Jul 21 2024 Cape Town, South Africa

Colombia Oil & Gas

Jul 24 2024 Bogata, Colombia

View all events