• VSA, membrane and PSA technologies for carbon capture from hydrogen production on refinery SMRs
    Rozenburg refinery, Rotterdam
  • Refinery at Port Arthur, Texas
  • Port Jerome refinery, France

Hydrogen fuel

VSA, membrane and PSA technologies for carbon capture from hydrogen production on refinery SMRs

Author credit – Stephen B. Harrison and Maria James, sbh4 consulting

Desulphurisation of refined products has become standard practice as liquid fuel specifications have become more stringent. Hydrotreating is a widely accepted technique in refineries to remove sulphur from various oil fractions and create marketable products such as Ultra Low Sulphur Diesel (ULSD).

Currently, the predominant production route of hydrogen for use in refineries is steam methane reforming (SMR). SMR uses natural gas or refinery gas as its feedstock and about 80% of current global hydrogen production is derived from fossil fuels, with SMR technology. Methane and steam are converted into syngas with a typical composition of 76% hydrogen, 17% CO2, and 7% unreacted methane and other gases. An SMR typically emits 9.5 kg of CO2 per kg of hydrogen, making hydrogen produced by SMRs from fossil fuels without carbon capture unsustainable.

Currently, CO2 is either emitted into the atmosphere or, in the production of ammonia for urea fertilizers, it is captured using an amine-wash process. Typically, in such cases, the flue gases are contacted against water to cool them and remove particulates. This is followed by a twin-tower of amine-based CO2 absorption and CO2 stripping. About 90% of the CO2 is removed from the flue gases which are emitted from the absorber. The stripper produces a high purity CO2 stream.

An amine wash system can be used for carbon capture on refinery SMRs. Alternative options are to use membranes and PSA or VSA adsorption systems to capture the CO2 emissions. Two process flow sheet options using this mix of technologies have been piloted at refineries in the USA and Europe to capture the CO2 content from the process gases leaving the SMR. In the first scenario, the hydrogen PSA does not separate any additional impurities after the SMR. In a second process flow sheet, the CO2 is sequestered from the hydrogen PSA tail gas. The very high CO2 concentration in the hydrogen PSA tail gas of more than 80% may make this process flow sheet favourable.

VSA CO2 capture from refinery SMR at Port Arthur, USA
To capture CO2 from the tail gas of the SMR hydrogen purification PSA unit, a vacuum swing adsorption VSA process has been implemented by Air Products at a refinery in Port Arthur, Texas. To capture the CO2 content of the product gas, the VSA unit has been inserted between the SMR and the hydrogen PSA unit. CO2 can be produced with a purity of 95% and a recovery rate of over 90%.

To function, the VSA adsorber vessels are sequentially fed with CO2-rich product gas at pressure and then depressurised to a vacuum to release the CO2 from the adsorbent material. CO2 is selectively adsorbed on the adsorbent bed and the hydrogen-rich gas that flows through the carbon capture VSA system is fed into the hydrogen PSA system for further purification.

To release the CO2, the pressure in the VSA adsorber vessel is reduced to below atmospheric pressure. Then the bed is returned to a higher-pressure bed to purge and clean the vessel. About 90% of the carbon dioxide is removed using this VSA equipment, which results in a million tonnes of CO2 being captured annually: a major contribution to decarbonising refinery hydrogen production.

At Port Arthur, the CO2 is then compressed by an intercooled 8-stage centrifugal compressor to about 70 bar, which is above the triple point of CO2. A 21 km CO2 pipeline leg connects the VSA units to an existing CO2 transmission pipeline that runs 500 km to oil fields in Texas and Louisiana where the captured CO2 is used for Enhanced Oil Recovery (EOR).

Membrane and PSA CO2 capture from refinery SMRs in Europe
Air Liquide has developed a CO2 sequestration method that captures CO2 from the CO2-rich tail gas from SMR hydrogen PSA units. In the first stage of the process, an additional PSA system removes water vapour from the PSA tail gas. Non-condensable gases go to a cryogenic membrane system, where additional hydrogen and CO2 are recovered.

The process increases hydrogen productivity by 10-20%, as well as achieving a CO2 recovery rate of more than 98%. Residual gases are sent back to the reformer burner, where their energy is used to drive the reforming reaction.

A demonstration plant using this process has been installed at the Port-Jérôme refinery in Normandy, France. It can capture 100,000 tonnes of CO2 per year. A planned second installation of the technology for an existing SMR at the Rozenburg refinery in Rotterdam will have a CO2 capture capacity of 500,000 tonnes of CO2 per year. Subject to FID and other project milestones, the Rozenburg refinery SMR carbon capture facility could be operational in 2024, making another huge contribution to the decarbonisation of refinery hydrogen production on SMR units.


Digital Edition

PIN 25.5 Oct/Nov 2024

November 2024

Analytical Instrumentation - Picturing Viscosity – How Can a Viscometer or a Rheometer Benefit You? - Sustainable Grease Formulations: Evaluating Key Performance Parameters and Testing Method...

View all digital editions

Events

Clean Fuels Conference

Jan 20 2025 San Diego, CA, USA

Smart Factory Expo 2025

Jan 22 2025 Tokyo, Japan

SLAS 2025

Jan 25 2025 San Diego, CA, USA

China Lab 2025

Feb 05 2025 Guangzhou, China

View all events