VOC measurements by IR cameras: Operational boundaries and model estimations
Infrared (IR) gas finder cameras are increasingly used in leak detection and repair (LDAR) surveys for detecting fugitive volatile organic compound (VOCs) emissions from process components. In order to use the camera for identifying leaking process components which have to be repaired, it is important to:
(1) operate the camera under conditions in which the IR camera's detection limit is expected to be lower than LDAR's repair thresholds;
(2) use the camera for determining whether a leaking inaccessible or remote process component exceeds its repair threshold.
In the present study, a laboratory facility was developed and used for determining the IR camera's detection limit as a function of multiple operating conditions, namely wind speed, viewing distance, and temperature difference between background and gas cloud. Operational boundaries were derived from the laboratory data for six different process components to ensure that the IR camera's detection limit is lower than the repair thresholds in LDAR. For determining whether a leak is inaccessible or the remote process component exceeds its repair threshold, an emission model was developed and validated with field data obtained in The Netherlands.
Speakers
Dr John Korsman (DCMR environmental protection agency)
Digital Edition
PIN 25.5 Oct/Nov 2024
November 2024
Analytical Instrumentation - Picturing Viscosity – How Can a Viscometer or a Rheometer Benefit You? - Sustainable Grease Formulations: Evaluating Key Performance Parameters and Testing Method...
View all digital editions
Events
Dec 03 2024 Dusseldorf, Germany
Dec 08 2024 Anaheim, CA, USA
Turkey & Black Sea Oil and Gas
Dec 11 2024 Istanbul, Turkey
Dec 19 2024 Aurangabad, India
Jan 20 2025 San Diego, CA, USA