Safety
Infrared Carbon Dioxide Point Detector Offers Reliable, Low Maintenance Plant Protection
Mar 04 2012
Offering reliable gas detection performance with low maintenance, the rugged Model IR700 Infrared Carbon Dioxide Point Detector from General Monitors requires no routine calibration and provides complete control room status and control capability for monitoring at the ppm level.
The Model IR700 features a precision IR point sensing element that offers reliable protection against the hazards of carbon dioxide gas leaks. The IR700 features a true fail-to-safe design for dependable gas detection performance, heated optics to eliminate condensation, and a dirty optics indicator informs the user the device must be cleaned before the lenses are entirely blocked, thereby reducing downtime.
Carbon dioxide is an inexpensive and versatile gas that is useful in diverse applications from beverage carbonation to enhanced oil recovery techniques. While nonflammable and fairly innocuous, leaks can be dangerous. Exposure to atmospheric concentrations above 5,000 ppm is considered unhealthy, making careful monitoring crucial at lower levels. Atmospheric concentrations at 1% (10,000 ppm) will make some people feel drowsy while concentrations of 7% and higher can lead to symptoms including dizziness, headache, visual and hearing dysfunction, and unconsciousness.
The Model IR700 IR detector features microprocessor-based technology to continuously monitor CO2 at a range of 0-5000 ppm. Its detection principle is based on measuring the absorption of infrared radiation passing through a volume of gas using a dual beam, single detector method. The IR detector measures the intensity of two specific wavelengths, one at an absorption wavelength and another outside of the absorption wavelength. Gas concentration is determined by a comparison of these two values.
All of the Model IR700’s electronics are contained within a rugged, explosion-proof housing so that detector information can be processed at the point of detection. It features multiple communication outputs, a 4-20 mA signal proportional to 0-100% full-scale, Modbus, and HART. The IR700 is also available with relays for warning, alarm, and faults.
The IR700 can be connected to an IR4000S CO2 transmitter to provide local display and control. The highly versatile IR4000S CO2 incorporates an LED, relay module, and magnetic interface in a rugged explosion-proof enclosure. Carbon dioxide concentrations are displayed in increments of 100 ppm. The IR4000S CO2’s rugged design permits installation and calibration in hazardous locations. Optional 8-A relays expand system functions, reducing the need for integration with other controllers.
The low-maintenance IR700 Carbon Dioxide Detector is factory-calibrated and requires no routine field calibration. Periodic window cleaning and re-zeroing are necessary to ensure performance. The IR700 is able to discriminate between true fault and cleaning requirements and stores fault, gas check, and alarm event history.
Digital Edition
PIN 25.5 Oct/Nov 2024
November 2024
Analytical Instrumentation - Picturing Viscosity – How Can a Viscometer or a Rheometer Benefit You? - Sustainable Grease Formulations: Evaluating Key Performance Parameters and Testing Method...
View all digital editions
Events
Nov 26 2024 Paris, France
Nov 26 2024 Amsterdam, Netherlands
Nov 27 2024 Istanbul, Turkey
Biogas Convention & Trade Fair 2024
Nov 27 2024 Hanover, Germany
Dec 03 2024 Dusseldorf, Germany