The Gassonic Observer-H Ultrasonic Gas Leak Detector from General Monitors is ideal for gas leak detection in pressurised systems. The new Gassonic Observer-H features HART communications, Modbus with single and block transfer modes, Emerson AMS Intelligent Device Manager support, and event logging. The Observer-H is ATEX, IECEx, FM and CSA hazardous area certified and SIL 3 suitable.
The Gassonic Observer-H detects gas leaks by sensing the airborne ultrasound emitted from leaking gas at high pressure. It is suitable for gas detection in open, well-ventilated areas, where traditional detection methods may be unsuitable or dependent on ventilation. Since the gas leak detector responds to the source of a gas release rather than the dispersed gas, it is unaffected by changing wind directions, gas dilution, and the direction of the leak. The Gassonic Observer-H’s wide coverage zone makes it possible to supervise areas up to a 20 meter radius, for the detection of leaks as small as 0.1 kg/sec., with only one device.
Rugged and designed for failsafe operation, the Gassonic Observer-H features robust microphone technology with an advanced stainless steel microphone. The detector also offers the Senssonic integrated acoustic self-test, which verifies the integrity of the instrument’s electric circuit and microphone every 15 minutes. It features stainless steel, AISI 316L explosion-proof housing, offering corrosion resistance in the harshest environments.
The Gassonic Observer-H features a sophisticated high pass filter to remove frequencies below 25 kHz, effectively eliminating interference from audible sound. At the same time, setting the alarm trigger level above the ultrasonic background noise ensures the detector accurately detects gas leaks. The Observer-H is equipped with a 3-digit LED display and an event logging function that stores fault, sound check, calibration, and alarm event history.
The versatile Gassonic Observer-H can be configured with an analogue output of Modbus or HART communications to provide complete status and control capability in the control room. The Modbus and HART data can also be used for predictive maintenance and to enable asset management and process improvement.
The Gassonic Observer-H detects leaks at a frequency range of 25-70kHz at a dynamic range of 58-104 dB. Detection coverage varies from 13-20 m radius in very low noise areas (<58 dB), 9-12 m radius in low noise areas (<68dB), to 5-8m radius in high noise areas (<78dB). Such distances are defined for a methane gas leak of 0.1 kg/s.
The Gassonic Observer-H operates at a temperature range of -40F to 140F (-40C to -60C) and at a humidity rand of 10 to 95% RH.
Digital Edition
PIN 25.5 Oct/Nov 2024
November 2024
Analytical Instrumentation - Picturing Viscosity – How Can a Viscometer or a Rheometer Benefit You? - Sustainable Grease Formulations: Evaluating Key Performance Parameters and Testing Method...
View all digital editions
Events
Nov 26 2024 Paris, France
Nov 26 2024 Amsterdam, Netherlands
Nov 27 2024 Istanbul, Turkey
Biogas Convention & Trade Fair 2024
Nov 27 2024 Hanover, Germany
Dec 03 2024 Dusseldorf, Germany