• How to Detect Combustible Gases

Safety

How to Detect Combustible Gases

Jul 04 2014

The most accurate way to detect combustible gases is by using a dedicated gas detector. It’s important to know that there are many detector varieties, some of which identify combustible gases and others toxic gases.

The types of combustible gas detectors include catalytic bead sensors, explosimeters, infrared point sensors and infrared open path detectors. The technology used in each of these is unique, so the gases are identified in different ways.

Depending on the atmosphere they intend to protect, gas detectors can either be portable or fixed (to a wall or ceiling, for example). The types of alarms also vary, but the most common detectors use sound, light or a combination of both to alert people to the presence of gas.

You can read more about the latest developments in gas detection in the article Incorporating Newer Technologies into Your Gas Detection Program.

The Different Types of Combustible Gas Detectors

Catalytic bead sensor

There are two platinum coils within a catalytic bead sensor that are connected to an alumina bead which creates a circuit. Two pellistors are used to create a catalyst that promotes oxidation in one and inhibits it in the other. Using this process, the detector is set to a fixed temperature. The presence of a combustible gas raises the temperature of the detector, triggering the alarm. This type of detection system takes only a few seconds to recognise gas in the atmosphere and is therefore very efficient.

Explosimeter

An explosimeter is a small, portable device used to detect combustible gases within a sample. Much like the catalytic bead sensor, this detector works on subtle temperature increases. A wire within the explosimeter is heated to a normal temperature that the detector is programmed to recognise as safe. When a gas is present in the atmosphere the temperature increases, the wire becomes hotter and the alarm is triggered.

Infrared point sensor

This detector works by transmitting two infrared signals onto a beam splitter. These signals pass through a measuring path and are then reflected so the detector can measure the gas in the atmosphere. If a combustible gas is present, one of the signals will be reduced. When the detector registers the difference between the two signals, the alarm will be triggered.

Infrared open path detector

Unlike the infrared point sensor, this detector uses a sensor that can reach hundreds of metres and detect a combustible gas anywhere along that path. These are sought after detectors because they detect gas within an expansive atmosphere rather than a specific point.

To find out more about the differences and benefits of these types of detectors, read the article Infrared vs. Catalytic Bead Technology: Pros and Cons


Digital Edition

PIN 25.2 Apr/May

May 2024

Safety - Carbon monoxide toxic and flammable gas detection Analytical Instrumentation - Density: A fundamental parameter at critical stages within the petroleum sector - Advancements and...

View all digital editions

Events

The World Biogas Expo 2024

Jul 10 2024 Birmingham, UK

Thailand Oil & Gas Roadshow 2024

Jul 11 2024 Rayong, Thailand

HPLC 2024

Jul 20 2024 Denver, CO, USA

ICMGP 2024

Jul 21 2024 Cape Town, South Africa

Colombia Oil & Gas

Jul 24 2024 Bogata, Colombia

View all events