Flow Level Pressure
Level, Flow and Interface with One Single Device Suited for SIP/CIP Applications
Jun 18 2008
liquids - gases or detect one liquid layer over another (interface).
The hygienic Thermatel® TD2 switch with a spherical tip sensor has passed the in-place cleanability testing according to the EHEDG procedures (European Hygienic Engineering and Design Group). The spherical sensor does not contain any shadow areaâs that cannot be cleaned with standard spray balls. The TD2 is available with an IP67, deep drawn 304 stainless steel enclosure.
Other TD2 compatible sensor options include mini twin tip sensors that can be mounted in âTâ- pieces as small as ½â size (25mm) or low flow bodies for in-line mounting in lines as small as ¼â (13mm). The low flow
body sensor is capable of detecting flows as low as 0,02 l/h in a ¼â pipe line.
The Thermatel® TD2 uses enhanced thermal dispersion technology with automatic temperature compensation. Automatic temperature compensation
reduces the set point drift at varying process temperatures and provides a highly repeatable switch. The TD2 adds on features such as continuous diagnostics, mA and relay output and local LED indication of flow. Thermatel® TD2 is able to withstand +200°C process temperature and pressures up to 41 bar (sensors for higher temperature/ pressure available).
Digital Edition
PIN 25.5 Oct/Nov 2024
November 2024
Analytical Instrumentation - Picturing Viscosity – How Can a Viscometer or a Rheometer Benefit You? - Sustainable Grease Formulations: Evaluating Key Performance Parameters and Testing Method...
View all digital editions
Events
Dec 03 2024 Dusseldorf, Germany
Dec 08 2024 Anaheim, CA, USA
Turkey & Black Sea Oil and Gas
Dec 11 2024 Istanbul, Turkey
Dec 19 2024 Aurangabad, India
Jan 20 2025 San Diego, CA, USA