Safety
Enhanced Version of Safety Instrumented System Released
Jul 05 2011
Yokogawa Electric Corporation (Netherlands) has announced the development of an enhanced version of the ProSafe-RS safety instrumented system that is used to ensure the safety of plant operations. This new version, ProSafe-RS R3.01, features input modules that can directly receive voltage signals from temperature sensors as well as software that restricts the operations performed by individual engineers and records a log on their activities. In addition, new compact terminal boards have been developed for use with the ProSafe-RS safety instrumented system. The compact terminal boards will be released in June and ProSafe-RS R3.01 will be released in July.
There is a growing demand in the oil, natural gas, petrochemical, iron & steel, and other energy and basic materials industries for safety instrumented systems that can help to ensure the safety of plant operations. This is driven by companies’ needs to provide a safe workplace, protect the environment, and be a responsible member of society.
In addition to looking for a reliable solution, companies that wish to install a safety instrumented system need to make maximum effective use of available space and have operation history management functionality that simplifies the task of identifying where problems are occurring in an operation. In response to these needs, Yokogawa has developed new modules and new terminal boards that are both reliable and compact, and software that improves operational safety. This new product lineup will meet Yokogawa’s customers needs for greater safety and reliability in their plant operations.
Ehancements in ProSafe-RS R3.01include temperature direct input modules. These new modules receive signals from mV, thermocouple (tc), and RTD sensors. In contrast to conventional modules, these modules do not require a signal converter to process the voltage signals from a temperature sensor. This enables a more compact design. These SIL3-certified modules provide highly reliable temperature monitoring.
Access control and operation history management software restricts the operations that can be performed by the individual engineers who are operating the ProSafe-RS safety instrumented system, and records a log on their activities. This makes it easy to identify the causes of problems, and is particularly useful in plants that have a large engineering workforce.
In addition, the DIN rail mounted ProSafe-RS terminal boards that connect to cables from field devices are approximately 60% smaller than our previous terminal boards. These newly developed boards can be installed either horizontally or vertically, allowing the most effective use of available space.
Digital Edition
PIN 25.6 Buyers' Guide
January 2025
Buyers' Guide Directory - Product Listings by Category - Suppliers Listings (A-Z) Articles Analytical Instrumentation - ASTM D7042: The Quantum Leap in Viscosity Testing Technology -...
View all digital editions
Events
Jan 20 2025 San Diego, CA, USA
Jan 22 2025 Tokyo, Japan
Jan 25 2025 San Diego, CA, USA
SPE Hydraulic Fracturing Technology Conference and Exhibition
Feb 04 2025 The Woodlands, TX, USA
Feb 05 2025 Guangzhou, China