Flow level pressure
Rotamass Coriolis Flowmeter with Added Interface
Apr 25 2012
Yokogawa (Netherlands) has extended the communication capabilities of the ROTAMASS 3 Coriolis flowmeter series, by adding a Modbus interface. Modbus communications via an RS-485 connection will be available in both Modbus RTU and ASCII transmission modes.
The fast and simple Modbus communication, at up to 57 kbit/s, enables access to all relevant process measurements including - but not limited to - mass/flow, density and temperature. All measurement variables are included as readable address registers.
Compared to other field communication protocols like FOUNDATION Fieldbus or Profibus, the Modbus protocol involves no costly changes to the conventional 4-20 mA wiring, allowing a point-to-point or multi-drop network to be realised with minimal effort.
In addition to the Modbus communication, the standard I/O interfaces such as 4-20 mA, pulse/frequency and status in/out are still available for control and/or monitoring purposes.
For easy configuration of meter measurements and settings, a free ROTAMASS Modbus communication tool will be delivered with each ROTAMASS. This software tool is equipped with different functions, clearly shown in an explorer view. Despite Modbus communication, all settings can be done by means of the indicator. Even simultaneous HART communication via HHT or FDT is possible.
The ROTAMASS Coriolis flowmeter is respected in the market for its superior “box in box” design, which guarantees decoupling of the device from external vibrations and stresses. With its two U-shaped and thick wall tubes, this device achieves an optimum measurement accuracy of ±0.1% of reading for liquids and ±0.5% for gases, and has excellent zero-point stability, even under tough conditions in the field.
The mass-flow measurement range of the ROTAMASS spans from 45 kg/h to 600 t/h. A unique density accuracy of ±0.0005 g/cm3 (±0.5 g/l) results from the real density being calibrated using different liquids and temperatures. ROTAMASS can handle applications involving temperatures from -200°C up to +350°C.
Every ROTAMASS model is available with a variety of process connections offering pressure rates up to 285 bar. The result is a range of instruments to suit every customer in terms of pressure loss, measurement accuracy and price.
Digital Edition
PIN 25.6 Buyers' Guide
January 2025
Buyers' Guide Directory - Product Listings by Category - Suppliers Listings (A-Z) Articles Analytical Instrumentation - ASTM D7042: The Quantum Leap in Viscosity Testing Technology -...
View all digital editions
Events
Jan 22 2025 Tokyo, Japan
Jan 25 2025 San Diego, CA, USA
SPE Hydraulic Fracturing Technology Conference and Exhibition
Feb 04 2025 The Woodlands, TX, USA
Feb 05 2025 Guangzhou, China
Trinidad and Tobago Energy Conference 2025
Feb 10 2025 Point Lisas, Trinidad